AN ORDINANCE
Adopting the National Electrical Code, 1981
by Reference and Amending Title 4, Chapter 7,
Sections 1-4 and Section 9 of the City Code
of the City of Evanston
WHEREAS, the City Council of the City of Evanston considers it
in the public interest to adopt as its standard for construction, alteration,
and installation of electrical work the National Electrical Code, 1981
Edition; and
WHEREAS, the City Council of the City of Evanston has caused
three (3) copies of the aforesaid Code to be kept on file in the office of
the City Clerk for public inspection for a period of more than thirty (30)
days prior to the adoption of this ordinance;
NOW, THEREFORE, BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY
OF EVANSTON, COOK COUNTY, ILLINOIS:
SECTION 1: That Title 4, Chapter 7, Section 1-4 and Section 9
of the City Code of the City of Evanston, 1979, as
• 1 amended, be further amended to read as follows:
4-7-1: ADOPTION OF NATIONAL ELECTRICAL CODE: Pursuant to authority
granted by Chapter 24, Section 1-2-4, Illinois Revised
Statutes, and pursuant to its home rule powers, the City of Evanston
hereby adopts, by reference, as criteria for the issuance of construction,
reconstruction, alteration or installation permits, the provisions of
the National Electrical Code, 1981 Edition.
4-7-2: APPLICATION OF REGULATIONS: The regulations of the National
Electrical Code, 1981 Edition, shall apply to all matters
concerning the construction, reconstruction, alteration or installation
of all electrical wiring apparatus, fixtures, machinery or devices,
and their service equipment, and shall apply to al] existing or proposed
buildings and structures in the City.
4-7-3: AMENDMENTS AND EXCEPTIONS TO THE CODE: The following sections
of the National Electrical Code, 1981 Edition, are amended
to read as follows:
(A) CHAPTER 3
1. Section 336-11, Devices of Insulating Material, is hereby
deleted in its entirety.
(B) CHAPTER 4
. 1. Section 410.8, Fixtures in Clothes Closets, is hereby amended
to read as follows:
"Section 410-8. Fixtures in Clothes Closets.
108-0-81
"(a) A fixture shall be installed in every clothes closet with
an area of eight (8) square feet or larger.
"(b) A fixture in a clothes closet shall be installed:
11(1) On the wall above the closet door, provided clear-
ance between the fixture and a storage area where
combustible material may be stored within the closet
is not less than 18 inches, or
"(2) On the ceiling over an area which is unobstructed
to the floor, maintaining an 18 inch clearance hori-
zontally between the fixture and a storage area where
combustible material may be stored within the closet.
"NOTE: A flush recessed fixture equipped with a solid
lens is considered to be outside the closet area.
"(c) Pendants shall not be installed in clothes closets."
2. Section 422-24, Unit Switches as Disconnecting Means, is
hereby amended to read as follows:
"Section 422-24 Unit Switches as Disconnecting Means.
"(a) Unit switches which are a part of an appliance shall not be
considered as taking the place of the disconnecting means required
by Part D (Control and Protection of Appliances) of this Article,
unless there are other means for disconnection as follows:
"(I) Multi -Family Dwellings. In multi -family (more
than two) dwellings, the disconnecting means shall be
within the apartment, or on the same floor as the apart-
ment, or on the same floor as the apartment in which the
• appliance is installed, and may control lamps and other
appliances.
"(2) Two -Family Dwellings. In two-family dwellings, the
disconnecting means may be outside the apartment in
which the appliance is installed. This will permit an
individual switch for the apartment to be used.
"(3) In Single -Family Dwellings. In single-family
dwellings, the service disconnecting means may be used.
"(4) Other Occupancies. In other occupancies, the branch -
circuit switch or circuit breaker, where readily accessible
to the user of the appliance, may be used for this purpose.
"(b) A dishwasher shall have a fused type "S" disconnect switch
readily accessible under the kitchen sink. A disposal without a
unit switch shall have a switch installed in the wall or under the
sink. Any changes from the provisions of this section (b) shall be
approved by the Director of Building & Zoning of the City of
Evanston."
4-7-4: DEFI14ITIONS: Any reference in the lawfully adopted Electrical
Code to "Administrative Authority" shall be read as meaning
the "Director of Building & Zoning of the City of Evanston.
4-7-9: PENALTY: Any person who shall violate any provisions of the
National Electrical Code, 1981 Edition, or who shall fail to
• comply with any of the requirements thereof, or who shall change, move
or alter any wiring apparatus, fixture, machinery, or device in violation
of any approved plan or direction of the Director of the Department of
Building & Zoning or of any permit or certificate issued under the pro-
visions of the National Electricaal Code, 1981 Edition, shall be guilty
-2-
•
0
•
of an offense, punishable by a fine of not less than fifty dollars
($50.00) or more than five hundred dollars ($500.00). A separate
offense shall be deemed committed for each day such violation shall
occur or continue.
SECTION 2: It is the intention of the City Council that the pro-
visions of this ordinance and the National Electrical
Code, 1981 Edition, are severable and the invalidity of any section or
part of any section of this ordinance and the Code hereby adopted shall not
affect any other section or portion of said ordinance or code.
SECTION 3: This ordinance shall be in full force and effect from
and after its passage in the manner provided by law.
SECTION 4: All ordinances or parts of ordinances in conflict
herewith are hereby repealed.