HomeMy WebLinkAboutORDINANCES-1981-106-O-8111/18/81
106-0-81
AN ORDINANCE
Adopting the B.O.C.A. Basic Plumbing Code
Fifth Edition, 1981, by Reference and
Amending Title 4, Chapter 6, Sections 1, 2 and 6
of the Code of the City of Evanston
0- WHEREAS, the City Council of the City of Evanston considers it
in the public interest to adopt as its standard for construction,
alteration, and installation of plumbing work the B.O.C.A. Basic Plumbing
Code, Fifth Edition, 1981; and
WHEREAS, the City Council of the City of Evanston has caused
three (3) copies of the aforesaid Code to be kept on file in the office of
the City Clerk for public inspection for a period of more than thirty (30)
days prior to the adoption of this ordinance;
NOW, THEREFORE, BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF
EVANSTON, COOK COUNTY, ILLINOIS
SECTION 1: That Title 4, Chapter 6, Sections 1, 2 and 6
of the Code of the City of Evanston, 1979, as amended,
be further amended to read as follows:
Q 4-6-1: ADOPTION OF THE B.O.C.A. BASIC PLUMBING CODE
(A) Pursuant to the authority granted by Chapter 24, Section 1-2-4
of the Illinois Revised Statutes and pursuant to its home rule
powers, the City of Evanston hereby adopts by reference the B.O.C.A.
Basic Plumbing Code, Fifth Edition, 1981, which code shall be used
with the below stated additions, amendments and deletions to govern
the issuance of permits and the standards of performance and
materials for the construction, alteration, and installation of
plumbing work in the City of Evanston.
(B) Any reference to "administrative authority," or "building official"
.shall mean the Director of Building and Zoning of the City of
Evanston. Any reference to "municipality" shall mean the City of
Evanston.
(C) Additions to the B.O.C.A. Basic Plumbing Code, 5th Edition:
P-801.1.2 Window wells: All window wells shall be provided with
drains. Window well drains may be connected to the drain tile and
drain into the sump pump.
P-308.2.1 All copper piping shall be protected against galvanic
(electrolitic) action by insulating it from any other metallic
contact and the use of dielectric unions.
P-313 Overhead plumbing: All new buildings erected after December
• 31, 1970, with basements, floors, rooms or occupancy areas below
ground level at the building site and served by a public or private
106-0-81
system shall have overhead plumbing. No building permit application
will be accepted nor any permits issued for construction of any
structure in a new building unless plans and specifications there-
for provide for overhead plumbing in accordance with this section.
P-314 Sill cocks: All buildings except accessory buildings
shall be provided with two sill cocks.
P-1219.1.1 Floor drains: The floor of every public water closet
or urinal compartment shall be graded to drain into any floor
type urinal, waste opening, or into a floor drain.
P-801.1.1 Footing drains: Footing drains shall be connected to
sump pumps and discharge shall be made through storm sewers,
combination sewers or drainage ditches. No footing drain or drainage
rile shall be connected to the sanitary sewer.
P-1219.1.2 Washing Machines and Hot Water Heaters: A pan or
receptor with a drain; or a floor drain in an impervious floor, shall
be required for all automatic machines and hot water heaters.
P-1222 Abandoned fixtures: Plumbing fixtures not maintained or
abandoned shall be disconnected, removed, and sealed.
(0) Amendments: The following sections of the B.O.C.A. Basic Plumbing
Code, 5th Edition, are amended to read as follows:
P-114.2 Fee Schedule: The permit fee for construction, reconstruc-
tion, alteration and installation shall be those established from
time to time by the City Council of the City of Evanston.
P-117.4 Penalties: Any person who shall violate a provision of
this code or shall fail to comply with any of the requirements there-
of or who shall install plumbing work in violation of an approved
plan or directive of the plumbing official, or of a permit or
certificate issued under the provisions of the code, shall be
subject to penalty as provided in section 4-6-6 of the City Code.
P-118.2 Unlawful continuance: Any person who shall continue any
plumbing work in or about the structure after having been served
with a stop work order, except such work as that person is directed
to perform to remove a violation or unsafe conditions, shall be
subject to penalty as provided in section 4-6-6 of the City Code.
P-303.2 Public systems available: A public water supply system
and/or public sewer system shall be deemed available to premises
used for human occupancy if such premises are within 1000 feet,
measured along a street, alley, or basement, of the public water
supply or sewer systems and a connection conforming with the
standards set forth.in this code may be made thereto.
P-308.3 Freezing: Water service piping and sewers shall be in-
stalled below recorded frost penetration, but not less below grade
than five (5) feet for water piping and four (4) feet below grade
for sewers. Plumbing piping in exterior building walls shall be
adequately protected against freezing by insulation or heat or
both.
P-313.1 Openings in fire resistance rated floors: The required
fire resistance rating of floor or floor/ceiling or wall assemblies
shall be maintained where a penetration is made for plumbing, pipes
and stacks.
Therefore, all piping going through a fire rated floor, ceiling or
wall shall be metallic pipe for a distance not less than two (2)
feet below and one (1) foot above said floor, ceiling or wall.
-2-
106-0-81
P-404.1.2 Water service pike: Water service pipe shall be made
of ductile iron pipe, cast iron pipe, copper pipe, or copper tube.'
Copper tube when used underground shall be "type K" and shall be
put together with cast bronze flared fittings. Water service pipe
shall conform to the applicable standards listed in Table P.-404.1.2
and shall have a minimum working pressure of 160 pounds per square
inch (160 psi/1103.04 kPa) at 73.4 degrees F. (23 degrees C).
P-404.1.3 Water distribution pipe: The water distribution system
shall be brass or copper pipe, copper tube, galvanized open hearth
iron pipe or galvanized steel pipe. Copper tube shall have a weight
of not less than copper water tube "type L." The water distribu-
tion pipe shall conform to the applicable standards listed in
Table P-404.1.3 and shall have a minimum pressure rating of 80 psi
(551.2OkPa) at 180 degrees F. (82 degrees C.).
P-404.2.4 Building sewer:
a. In a trench separate from water service: If the building
sewer is installed in a trench separate from the water service, the
sewer pipe shall be of cast iron, concrete, vitrified clay tile,
truss pipe or ductile iron pipe. Joints shall be watertight and
root proof. Metropolitan Sanitary District standards shall be
followed.
b. In trench with water service: If the building sewer is ire -
stalled in the same trench as the water service, the conditions
of Section P-1502.2.1 shall be met. Metropolitan Sanitary District
standards shall be followed.
(E) Deletions: The following section of the B.O.C.A. Basic Plumbing
Code, 1981 Edition,.is hereby deleted:
P-122.0 Means of Appeal
• (F) Application: The provisions of the B.O.C.A. Basic Plumbing Code and
the provisions of this ordinance shall be deemed to apply to all
matters concerning the design, installation, alteration, addition,
repair, removal, construction, use, location, and maintenance of
plumbing systems, sanitary and storm and sewage disposal in ser-
vicing existing and proposed buildings or structures in the city.
4-6-2 CAR WASH FACILITIES: All car wash facilities constructed in the
City of Evanston and all replacements of existing fixtures in car
wash facilities shall be equipped with water recycling systems, except
when it is clearly demonstrated that the design and operation of the
facility uses less than thirty (30)gallons of water per wash.
4-6-6: PENALTY: Any person who shall install, extend, alternate, repair
or maintain plumbing systems in or adjacent to buildings except in
conformity with the provisions of the B.O.C.A. Basic Plumbing Code, Fifth
Edition, as adopted, shall be guilty of a violation punishable by a fine
of not less than fifty dollars ($50.00) nor more than five hundred
dollars ($500.00) for each offense. A separate offense shall be deemed
committed for each day that an offense continues.
SECTION 2: It is the intention of the City Council that the pro-
visions of this ordinance and the B.O.C.A. Basic
Plumbing Code are severable and the invalidity of any section or part of any
section of this ordinance and the code hereby adopted shall not affect any
other section or portion of the said ordinance or code.
-3-
law.
106-0-81
SECTION 3: This ordinance shall be in full force and effect
from and after its passage in the manner provided by
SECTION 4: All ordinances or parts of ordinances in conflict
herewith are hereby repealed.
Introduced: /� , 1981.
Adopted: v� , 1981.
ATTEST:
1
s
City Cle k
ApprovWorati-oon
• Counsel
;
Ll
Approved: 1981.
ii V i
r ✓ MW
-4-