HomeMy WebLinkAboutORDINANCES-1986-082-O-867/16/86 • • 1 M AN ORDINANCE Amending Section 4-7-3 (B) of the City Code Pertaining to Amendments and Exception to the National Electrical Code BE IT ORDAINED BY.THE CITY COUNCIL OF THE CITY OF EVANSTON, COOK COUNTY, ILLINOIS: SETION 1: That'Section 4-7-3 (B) of the City Code of the City of Evanston, 1979, as amended, be and -it is hereby further amended by adding the following subparagraph 4. 4. Exceptions: 1. Lighting fixtures and lighting outlets located 12 feet (3.66 m) or more above the maximum water level shall not require protection by a ground -fault circuit -interrupter. 2. Lighting fixtures other than the pendant or hanging type shall be permitted above a one -person hydro -massage bathtub in a bathroom if all of the following provisions are'met: (a) The fixture is of the totally enclosed type; (b) The distance from the bottom of the fixture to the maximum water level is not less than 5 feet (1.52 m); (c) The fixture is rigidly attached to the wall or ceiling; and (d) A ground -fault circuit -interrupter is installed in the branch circuit supplying the fixture(s). SECTION 2: All ordinances or parts of ordinances in conflict herewith are hereby repealed. SECTION 3: This ordinance shall be in full force and effect from and after its passage, approval, and publication in the manner provided by law. Introduced: 1986. Adopted:1986. U 1986. Appr d: Mayor ATTEST: _ • / Ci _y Clerk Ap oved as to form: Corpor lion counsel