Loading...
HomeMy WebLinkAboutORDINANCES-1990-080-O-9080-0-90 AN ORDINANCE Adopting the B.O.C.A. National Plumbing Code Eighth Edition, 1990, by Reference and Amending Title 4, Chapter 6, Sections 1, 3, and 6 of the City Code of. the City of Evanston WHEREAS, THE City Council of the City of Evanston considers it in the public interest to adopt as its standard for construction, alteration, and installation of plumbing work, the B.O.C.A. National Plumbing Code, Eighth Edition, 1990; and WHEREAS, the City Council of the City of Evanston has caused three (3) copies of the aforesaid Code to be kept on file in the office of the City Clerk for public inspection for a period of more than thirty (30) days prior to the adoption of this ordinance; NOW, THEREFORE, BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF EVANSTON, COOK COUNTY, ILLINOIS: Section 1: That Sections 4-6-1 (A) and (B) of the Code of the City of Evanston, 1979, as amended, be further amended to read as follows: 4-6-1: ADOPTION OF THE B.O.C.A. NATIONAL PLUMBING CODE: (A) Pursuant to the authority granted by Chapter 24, Section 1-2-4 of the Illinois Revised Statutes and pursuant to its home rule powers, the City of Evanston hereby adopts by reference the B.O.C.A. National Plumbing Code, Eighth Edition, 1990, which code shall be used with the below - stated additions, amendments, and deletions to govern the Issuance of permits and the standards of performance and materials for the construction, alteration, and • installation of plumbing work in the City of Evanston. (B) Any reference to "administrative authority, or building official" shall mean the Director of Building and Zoning of the City of Evanston. Any reference to "municipality" shall mean the City of Evanston. SECTION 2: That Section 4-6-1(C) of the Code of the City of Evanston, 1979, as amended, be further amended to read as follows: Section P1218.11 Sill Cocks is changed to P1223.4 Sill Cocks: All buildings except accessory buildings shall be provided with two (2) sill cocks. Section P1219.1.1 Floor Drains is changed to P1211.1.1 Floor Drains: The floor of every public water closet or urinal compartment shall be graded to drain into any floor - type urinal, waste opening or into a floor drain. Section P1219.1.2 Washing Machines and Hot Water Heaters, is changed to 1211.1.2 Washing Machines and Hot Water Heaters: A pan or receptor with a drain; or a floor drain in an impervious floor, shall be required for all automatic machines and hot water heaters. Section P1222.2 Abandoned Fixtures is changed to 1224.0 Abandoned Fixtures: Plumbing fixtures not maintained or abandoned shall be disconnected, removed and sealed. (Ord. 84-0-84) to read as follows: SECTION 3: That Section 4-6-1D of the Code of the City of Evanston, 1979, as amended, be further amended Amendments: The following section of the B.O.C.A. National. plumbing Code, Eighth Edition, are amended to read as follows: P-402.3 Water Service Pipe is changed to P402.4 Water is iron Pipe: Water service pipe shall be made of ductile iron pipe, cast iron pipe, copper pipe or copper tube. Copper tube, when used underground, shall be "type K" and shall be put together with cast bronze flared fittings. Water service pipe shall conform to the applicable standards listed in Table P-402.4 and shall have a minimum working pressure of 160 pounds per square inch (160 psi/1103kpa) at 73.4 degrees F. (23 degrees C). P-402.4 Water Distribution Pipe is changed to P-402.5 Water Distribution Pipe: The water distribution system shall be brass or copper pipe, copper tube, galvanized open hearth iron pipe or galvanized steel pipe. Copper tube shall have a weight of not less than copper water tube "type L." The water distribution pipe shall conform to the applicable standards listed in Table P-402.5 and shall have a minimum pressure rating of 80 psi (551.20kPa) at 180 degrees F. (82 degrees C.). (Ord. 108-8-87) P-404.2.3 Building Sewer - In a Trench Separate From Water Service is changed to P-403.3.3 Building Sewer - In a Trench Separate From Water Service: If the building sewer is installed in a trench separate from the water service, the sewer pipe shall be of cast iron, concrete, vitrified clay tile, truss pipe or ductile iron pipe. Joints shall be watertight and root -proof. Metropolitan Water Reclamation District standards shall be followed. (Ord. 84-0-84) 0 SECTION 4: amended to read as follows: to read as follows: to read as follows: That Section 4-6-1(E) of the Code of the City of Evanston, 1979, as amended, be further Deletion: The following section of the B.O.C.A. National plumbing Code, 1990, is hereby deleted. P-122.0 Means of Appeal SECTION 5: That Section 4-6-3 of the Code of the City of Evanston, 1979, as amended, be further amended NONMETALLIC PIPE MATERIALS IN WATER SERVICE PROHIBITED: Notwithstanding any of the provisions of the B.O.C.A. National Plumbing Code 1990 to the contrary, the use of nonmetallic pipe materials in water distribution services is hereby prohibited. (Ord. 80-0-79; and. Ord. 84-0-84) SECTION 6: That Section 4-6-6 of the Code of the City of Evanston, 1979, as amended, be further amended PENALTY: Any persons who shall install, extend, alter, repair or maintain plumbing systems in or adjacent to buildings except in conformity with the provisions of the is adopted, National Plumbing Code, Eighth Edition 1990, as adopted, shall be guilty of a violation punishable by a fine of not less than fifty dollars ($50.00) nor more than five hundred dollars ($500.00) for each offense. A -2- • • • separate offense shall be deemed committed for each day that an offense continues. (Ord. 108-0-87) SECTION 7: It is the intention of the City Council that the provisions of this ordinance and the B.O.C.A. National Plumbing Code are severable and the invalidity of any section or part of any section of this ordinance and the code hereby adopted shall not affect any other section or portion of said ordinance or code. SECTION 8: All ordinances or parts of ordinances in conflict herewith are hereby repealed. SECTION 9: This ordinance shall be in full force and effect from and after its passage, -approval, and publication in the manner provided by law. Introduced: 7 1990 Adopted: /� D 1990 Approved / 1990 Mayor ATTEST: City Clerk ;� J Appro ed as to fo !--ACorLnporation Co sel 0378C -3-