HomeMy WebLinkAboutMinutes 2000ELECTRICAL COMMISION MINUTES Thursday March 16, 2000 Room 2404 Members Present: Zeno Ivy (Electrical Engineer), Brian Lamberg (Electrical Contractor), John Wilkinson (Fire Chief), Jeff Zich (Chief Electrical Inspector and Chair). Members Absent: James Walker (Electrician) J. Zich. ( chair) determined a quorum existed and began meeting at 7:00 p_m. First Items for consideration Delete these articles in their entirety. Article 352-(b) Surface Nonmetallic Raceways Article 362-(b) Nonmetallic Wireways J. Zich= We are here to determine if we should delete articles 352-b and 362-b.in their entirety As we all know these wireways and raceways are not electrically continuous and should not be allowed tta be used for line voltage electric. Also these raceways are made of A.V.C. plastic type material that when exposed to fur or intense heat emits a poisonous smoke. • B. Lamberg. Don't they have to pass some kind of tests? J. Zich. They all get tested, but the testis limited to certain widths and lengft of material, in most cases the quantity of material installed on a typical job exceeds the amount of material used for testing. J. Wilkinson . I agree, it creates a trap for fireman and people that could be caught in afire situation. Z. Ivy. I believe all wire ways should be installed in some kind of metal raceway, the city of Chicago has been doing this for years. J. Zich. I motion to recommend the city delete art. 352-B and 362-B in their entirety. J. Wilkinson . I second Committee approved the motion. Second Item for consideration Amend Article 4I0-16 ( c ) J. Zich_ At this time the N.E.0 requires that fixtures installed in a suspended ceiling shall be fastened framing members of the ceiling. I believe in case of fire or any other reason the ceiling might come down. The best way to secure fixft= should be to the structure by means of pencil rod type wire or threaded rod. J. Wilkinson . I never could under stand why it was done that way. J. Zich. I think in some areas the possibility of earth quacks exists and of course the code is national. B. Lamberg. That's probably right. going to the structure is not mucus mom work and it would be safi r • Z. Ivy. I agree. J. Zich. I motion to recommend the city amend an 410-16 (c) to suM-tn fixtures it) the uructure. Z. ivy. 1 second Committee approved the motion Third Item for consideration Implementation of Home Owners Electrical Exam J. Zich Because of the number of homeowners doing their own electrical work 1 believe we need some kind of test to qualify them. The number of jobs that don't pass and the amount of work that's being done that the electrical inspectors basically have to engineer for them is getting out of hand. We are not supposed to do the work for them because at this time they sign an affidavit stating they arc qualified to do the work. J. Wilkinson It's about time we started something like this after all electricity kills, and in the case of fire the next door nieghbors will be involved for no reason other than a unqualified person did the work. B. Lamberg I had to work very hard to get my license and invest years of work to become qualified to do electrical work, so I believe a test is the least we should require. Z. Ivy. All trades require years of work and education before they arc allowed to work unsupervised so I think a test is not asking too much. J. Wilkinson We should include a disclaimer stating this is not a license and allows them to do only.the • work listed on the permit they are applying for. J. Zich. I think that would be a good idea, we could make it good for one year. B. I.amberg. One year would be more than enough. J. Zich. I motion to recommend we start giving the home owners electrical test with disclaimer. B. Lamberg. 1 second. Committee approved motion. J. Zich. 1 motion to adjourn J. Wilkinson I second Meeting adjourned at 9:15 p.m. Respectfully Submitted effre R Zich Chief Electrical Inspector