Loading...
HomeMy WebLinkAboutORDINANCES-1977-116-O-77• 116-0-77 AN ORDINANCE Adopting Certin Modifications To The BOCA Plumbing Code WHEREAS, the Illinois Department of Transportation has determined that all users of Lake Michigan Water must limit their use of this natural resource; and WHEREAS, pursuant to this determination the Illinois Department of Transportation has.issued an order specifying that all governmental bodies must take steps to conserve water, these steps include the adoption of ordinances which call for the in- stallation of certain types of plumbing fixtures in new construc- tion or in the replacement of existing equipment; NOW, THEREFORE, BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF EVANSTON: SECTION 1: That Article III of Chapter 10 of the Municipal Code of the City of Evanston, 195',; as amended, be further amended by .the following additions to the BOCA Plumbing Code adopted by reference in Chapter 10 of the Muni- cipal Code of the City of Evanston: • a) "Section P-1205.5. All flushometer and/or tank - type urinals shall be of a water conserving nature and operate at a rate not to exceed 3.0 gallons maximum per flush." 116-0-77 b) "Section P-1601.3. Every building equipped with • plumbing fixtures and used for human occupancy or habitation shall be provided with a:water saving de- vice on all plumbing fixtures. These fixtures shall not utilize a water flow rate in excess of the max- imum rates published by the Illinois Department of Transportation in Rules and Procedures for Lake Mich- igan Allocation, or as may be forthcoming from the Secretary of Housing and Urban Development, pursuant to the Energy Conservation Standards for New Build- ings (P.L. 94-385)." r_l LJ c) "Section P-1207.3. The water supply to sinks in public facilities shall be equipped with self -closing faucets which will not permit the unattended faucet to be left in the open position." d) "Section P-1209.1.1. Every shower shall be equ ip- ped with a limited flow shower head of a water con- serving nature, and operate at a rate not to exceed 3.0 gallons per minute." e) "Section P-1210.2. The water supply to sinks shall be equipped with water saving devices that use aerators plus restrictors to operate at a rate not to exceed 3.0 gallons per minute." SECTION 2: That Article III of Chapter 10 of the Muni-_ ci_pal Code of the City of Evanston, 1957 as amended be further amended by the substitution of the following sections for those sections of the Code contained in the BOCA basic Plumbing Code, Third Edition, 1975, adopted by reference in Chapter 10 of the Municipal Code of the City of Evanston: "P-1206.2 Flushometer valves: Flushometers shall be installed so that they will be readily accessible for repair. Flushometer valves shall not be used where the water pressure is insufficient to properly operate them. When the valve is operated, it shall complete the cycle of operation automatically, opening fully and closing positively under the water line pressure. Each flushometer shall be provided with a means for regulating the flow through it at a rate not to exceed 3.0 gallons per flush. -2- r 116-0-77 • "P-1206.3.1 Water for flushing: An adequate quan- tity of water shall be provided to flush and clean the fixture served. Water supply to flush tanks shall be made in accordance with Section P-1605.0. Pipes, connections and fittings between tanks and water closets or urinals shall be of adequate size to provide sufficient flow for proper flushing and cleaning of the fixtures. Where flush tanks are equipped for manual flushing, they shall be control- led by a float valve or other automatic device de- signed to refill the tank after each discharge, and to completely shut off the water flow to the tank when the tank is filled to operational capacity. Provision shall be made to automatically supply water to the fixture so as to refill the trap seal after each flushing. The water supply to flush tanks equipped for automatic flushing shall be controlled by a suitable timing device to thus act as a water conserving device and prohibit the valve from remain- ing in an open position. "P-1206.3.2 Flush valves in flush tanks: Flush valve. seats in tanks for flushing water closets shall be at least one (1) inch above the flood level rim of the bowl connected thereto, except in approved water clo- set and flush tank combinations designed so that when the tank is flushed and the fixture is clogged or par- tially clogged, the flush valve will close tightly so that the water will not spill continuously over the rim of the bowl or backflow from the bowl to the tank. Water closets for flush tanks shall be of a water con- serving nature and operate at a rate not to exceed 3.5 gallons maximum per flush." SECTION 3: That Chapter 10 of the Municipal Code of the City of Evanston, 1957, as amended be further amended by the addition of the following: "Section 10-20.1 All car wash facilities constructed in the City of Evanston and all replacements of existing fixtures in car wash facilities shall be equipped with water recycling systems." -3- s 116-0-77 • SECTION 4: All ordinances or parts of ordinances in conflict herewith are hereby repealed. ft SECTION S: This ordinance shall be in full force and effect from and after its passage, approval, and publication in the manner provided by law. Introduced �� S" , 1977 Adopted 12,- , 1977 Approved /,C ,. 1977 ATTEST: City`Clerk Approved as to form:2� Corporation Counsel -4-